Subterra Series Tier 15 Handhole (32x44x24 ID)

e.g. RUS

Approved

Compliant

Made in USA

The Subterra Max Tier 15 handhole in the 32x44x24 internal size widens the working footprint for mixed-load sites while keeping a 24-inch depth. The HDPE base and Impact Modified Resin lid hold Tier 15 loads at around 108 lb. The larger plan area suits multi-duct entries and bigger splice cases in utility corridors and shoulders, with cable management, locating puck and branding options.
  • Fast delivery guaranteed

Description

The Subterra Max Tier 15 handhole in the 32x44x24 internal size is the wide-footprint option in Norvant’s mid-tier line. It keeps the 24-inch working depth of the core size but opens the plan area to 32 by 44 inches, giving crews more room for multiple duct entries, larger splice cases and cable racking on mixed-load routes that do not warrant Tier 22. The HDPE base and Impact Modified Resin lid deliver dependable Tier 15 performance at around 108 lb, so the wider unit still installs quickly without heavy lifting gear. An anti-heaving ribbed sidewall design locks the unit into backfill to stop settling after install, and internal ribbing adds strength under working ground. Like the rest of the Max Tier 15 range, it accepts cable management, an optional locating puck and a custom logo plate or color, keeping hardware and branding consistent across a build. Engineered to meet ANSI/SCTE 77 Tier 15 and BABA and BEAD compliant, it is ready for federally funded mid-tier programs and shares its spec and option set with the 24x36x24 and 32x44x45 variants.

Dimension

x

x

inches

Weight

Lid:

lb

Base:

lb

Material

e.g. HDPE

Benefits

  • Telecom network operators
  • Fiber contractors
  • Municipal broadband projects

Applications

  • Fiber FTTH
  • Fiber Backbone
  • Telecom Access

Environments

  • Roadways
  • Shoulders and verges
  • Utility corridors

Why us icon

Specifications

Technical specifications and dimensions

Every detail engineered for field performance and cost efficiency. Tier 3 delivers the capacity and durability that networks demand.

Dimension

x

x

inches

Weight

Lid:

lb

Base:

lb

Material

e.g. HDPE

Options Available:


Why us icon

Comparison

Norvant Design Innovation vs Standard Handhole Features

See how Tier 3 stacks up on capacity, lead time, installation, and compliance.

Design Feature

Why This Matters

Norvant Solution

Standard Market Offerings

Lid Security in Flood Conditions

Heavy rain causes vaults to flood, pressure buildup lifts lids into traffic or they float away

Auto-Latch System – automatic locking prevents lid displacement under pressure

Manual friction-fit lids that can dislodge; requires separate locking mechanisms or weighted lids

Ground Movement Protection

Freeze-thaw cycles and soil heaving push vaults upward, breaking seals and damaging installations

Flared Anti-Heaving Base Design – wider footprint resists vertical displacement from frost and water action

Straight-wall designs rely on weight alone; vulnerable to seasonal ground movement

Structural Strength

HDPE is lightweight but must withstand Tier 22 load ratings (33,750 lbs) without flexing

Ribbed Sidewall Engineering – internal reinforcement maintains structural integrity at lower weight

Smooth walls requiring thicker material or composite reinforcement to achieve same load rating

Working Space for Splicing

High-density fiber deployments need room for splice cases, slack storage, and future cable additions

25% Larger Internal Capacity at same price tier – future-proofs against network growth

Standard internal dimensions force premature change-outs as take-rates increase

Asset Location & Management

Field crews waste time locating buried infrastructure; asset databases become outdated

Designed for Locating Puck Integration – optional sensor enables GPS mapping and digital asset management

No provisions for tracking technology; relies on paper maps or technician memory

Design Feature

Lid Security in Flood Conditions

Why This Matters

Heavy rain causes vaults to flood, pressure buildup lifts lids into traffic or they float away

Norvant Solution

Auto-Latch System – automatic locking prevents lid displacement under pressure

Standard Market Offerings

Manual friction-fit lids that can dislodge; requires separate locking mechanisms or weighted lids

Design Feature

Ground Movement Protection

Why This Matters

Freeze-thaw cycles and soil heaving push vaults upward, breaking seals and damaging installations

Norvant Solution

Flared Anti-Heaving Base Design – wider footprint resists vertical displacement from frost and water action

Standard Market Offerings

Straight-wall designs rely on weight alone; vulnerable to seasonal ground movement

Design Feature

Structural Strength

Why This Matters

HDPE is lightweight but must withstand Tier 22 load ratings (33,750 lbs) without flexing

Norvant Solution

Ribbed Sidewall Engineering – internal reinforcement maintains structural integrity at lower weight

Standard Market Offerings

Straight-wall designs rely on weight alone; vulnerable to seasonal ground movement

Design Feature

Working Space for Splicing

Why This Matters

High-density fiber deployments need room for splice cases, slack storage, and future cable additions

Norvant Solution

25% Larger Internal Capacity at same price tier – future-proofs against network growth

Standard Market Offerings

Standard internal dimensions force premature change-outs as take-rates increase

Design Feature

Asset Location & Management

Why This Matters

Field crews waste time locating buried infrastructure; asset databases become outdated

Norvant Solution

Designed for Locating Puck Integration – optional sensor enables GPS mapping and digital asset management

Standard Market Offerings

No provisions for tracking technology; relies on paper maps or technician memory